      The fix for EZP-20845 has introduced a regression, and actually highlights a problem: the shutdown handlers are executed twice if you call cleanExit() in a module / script (ezjscore does so, many modules that don't output HTML do).

      It also happens that when they're executed by ezpKernelWeb::shutdown(), the working directory is wrong (set to / in a pure legacy environnement).